• Low voltage pole mounted circuit breaker D165T with digital trip unit
Low voltage pole mounted circuit breaker D165T with digital trip unit
discuss personally
Model
D165/4
Basic info
Brand Wone Store
Model NO. Low voltage pole mounted circuit breaker D165T with digital trip unit
Rated normal current 165A
Rated frequency 50/60Hz
Series D
Product Detail

Description

These breakers are designed to operate within low - voltage networks, typically handling voltages of 600V AC or less and 750V DC or less. Their primary function is to interrupt the flow of current when faults such as overloads, short - circuits, or under - voltage conditions occur. They are widely used in various applications, including industrial plants, commercial buildings, and residential electrical systems. In industrial settings, they protect large - scale machinery and equipment from electrical malfunctions. In commercial buildings, they ensure the safety of lighting, heating, and cooling systems. In residential areas, they safeguard household appliances and wiring.

Features

  • Safe Circuit Interruption:LV circuit breakers are engineered to open and close circuits safely. This is vital as improper circuit interruption can lead to electrical arcs, which may cause fires or damage to equipment. They can handle the high - energy surges associated with breaking an electrical circuit without endangering the surrounding environment.

  • Repeated Breaking Operations:They are capable of performing breaking operations repeatedly. This feature ensures long - term reliability. In a power system where faults may occur occasionally, the breaker needs to be able to respond multiple times without degradation in performance. For example, in an industrial facility with fluctuating electrical loads, the breaker may need to trip and reset several times over its lifespan.

  • Multiple Electrode Breaking:Many LV circuit breakers can break multiple electrodes simultaneously. In complex electrical setups, such as three - phase power systems, this ability allows for the quick and effective isolation of all live conductors during a fault. This helps in preventing the spread of electrical faults and reduces the risk of damage to connected equipment.

  • High Breaking Capacity:Some models possess high breaking capacities. This is especially important in industrial and commercial applications where large short - circuit currents can occur. For instance, in a manufacturing plant with high - power machinery, a short - circuit could generate a substantial amount of current. A breaker with a high breaking capacity can safely interrupt this large current, protecting the entire electrical infrastructure.

Main Parameters

Dimensions

Weight

17 kg

Height

550 mm

Width

370 mm

Length

400 mm

Standards

Standards

HN 63-S-11

Electrical values

Rated Voltage (Ur)

0.44 kV

Rated current

165 A

Rated short-circuit breaking capacity

4 kA

Rated short-circuit making current

6.8 kA

Rated short-time withstand current (1s)

4 kA/s


10 kV

Lightning impulse withstand level of voltage (1.2/50)

20 kV

Features

Degree of protection

IP31

Output number

1

Conductor size

25 - 70mm²

Temperatures

Operating temperature

-25 ... 50 °C

Storage temperature

-25 ... 70 °C

Know your supplier
Wone Store
Main Categories
High Voltage Electrical Apparatus/Low Voltage Electrical Apparatus/Wire cable/Instrument meters/New energy/Tester/Production equipment/Generator/Electrical fittings/Integrated Electrical Equipment/Instrument Transformer/Equipment Parts
Business Type
Sales
Highest Annual Export (USD)
$300000000
Professional Experience
1 years
Workplace
1000m²
占位
占位
Related Products
Related Knowledges
Analysis of Abnormal Causes of High-Voltage Cable Grounding Circulation and Typical Cases
Analysis of Abnormal Causes of High-Voltage Cable Grounding Circulation and Typical Cases
I. Introduction to Cable Grounding Loop CurrentCables rated 110 kV and above use a single-core structure. The alternating magnetic field generated by the operating current induces a voltage on the metallic sheath. If the sheath forms a closed circuit through the earth, a grounding loop current will flow on the metallic sheath. Excessive grounding loop current (loop current exceeding 50 A, more than 20% of the load current, or a ratio of maximum-to-minimum phase current greater than 3) not only a
Felix Spark
09/03/2025
Considerations and Recommendations for Flame-Retardant Selection of High-Voltage Cables
Considerations and Recommendations for Flame-Retardant Selection of High-Voltage Cables
1.Flame-Retardant Cable Classification StandardsThe flame-retardant standard system is divided into two main categories. The first category follows the "Classification of Burning Behavior for Electric and Optical Fiber Cables" GB 31247. Cables complying with this standard system are widely used in densely populated areas such as high-speed railways and subways. This standard imposes strict requirements on parameters such as smoke density, heat release, and total smoke production, and cables typi
James
09/03/2025
Repair of high-voltage cable metallic sheaths
Repair of high-voltage cable metallic sheaths
I. Functions of Metallic Sheaths and Necessity of RepairThe metallic sheath of high-voltage cables is a metal shielding structure laid outside the insulation layer, including types such as lead sheaths, aluminum sheaths, and steel wire armor. Its core functions include mechanical protection (resisting external impact and compression), electrochemical corrosion protection (isolating moisture and soil pollutants), electromagnetic shielding (reducing electromagnetic interference to the environment)
Felix Spark
09/03/2025
What factors need to be considered when designing a transformer?
What factors need to be considered when designing a transformer?
Transformer design is a complex process that requires consideration of multiple factors to ensure safe and efficient operation. In addition, compliance with international and local regulations is essential to guarantee that transformers meet safety and performance standards. Below are key factors to consider in transformer design and the relevant regulations to follow:Transformer Design Factors: Voltage and Frequency: Determine the input and output voltage levels and the operating frequency. The
Vziman
09/02/2025
What failure modes are possible in a transformer? How to identify and fix these failures?
What failure modes are possible in a transformer? How to identify and fix these failures?
Transformers are critical components in power systems, and various failure modes can affect their operation. Timely identification and resolution of these failure modes are essential to prevent costly downtime and ensure system reliability. Below are some common transformer failure modes, along with methods to identify and address them: Insulation FailureIdentification: Insulation failure leads to decreased insulation resistance, which can be detected through insulation resistance testing (megge
Edwiin
09/02/2025
A hybrid DC circuit breaker
A hybrid DC circuit breaker
Most DC molded-case circuit breakers use natural air arc extinction, and there are typically two arc extinguishing methods: one is conventional opening and closing, where the contacts axially stretch the arc, while the conductive circuit generates a magnetic field that bends and elongates the arc, pulling it lengthwise perpendicular to the arc axis. This not only increases the arc length but also induces lateral motion, enabling air cooling to achieve arc extinction.The other method involves the
Echo
09/02/2025
×
Inquiry
Download
IEE-Business is dedicated to serving the personnel in the global power industry.
Join IEE-Business, not only can you discover power equipment and power knowledge, but also canhnd like - minded friends!